DESCRIPTION
Rocky no. 169
Rocky no. 169 is a mid grey with which you will rock your interior. With this shade you go for a neutral base and you can still go in all directions. Combine Rocky no. 169 with other neutrals such as Pale Grey no. 93 and Loft no. 113 or seek excitement with Tout no. 530 and Terra Pink no. 102 .
LAB Bathroom Coating
LAB Bathroom Coating is an easy to use system specially developed for bathrooms and wet cells, such as the shower room (with the exception of the floor in the wet cell). Ideal if you do not want tiles. But can also be applied over tiles! The LAB Bathroom Coating system consists of three different products, namely: LAB Bathroom Coating Impregnator, LAB Bathroom Coating Primer and LAB Bathroom Coating.
It is important to read the product advice carefully before application!
LAB Bathroom Coating Impregnation
With LAB Bathroom Coating Impregnator you fix powdery surfaces and highly absorbent surfaces are quickly sealed. This makes the covering system of LAB Bathroom Coating easier and more even to apply and creates a good bond with the surface.
Is the surface not absorbent? Then this step is not necessary.
Consumption: 6 to 10 m² per kilo. The yield depends on the substrate, pretreatment, method of application, applied layer thickness, processing material and conditions. Apply LAB Bathroom Coating Impregnator in 1 layer.
LAB Bathroom Coating Primer
LAB Bathroom Coating Primer provides excellent adhesion and colour coverage. For absorbent surfaces, first treat the bathroom with LAB Bathroom Coating Impregnation. If the surface is not absorbent (such as tiles and bathrooms that have already been painted or coated), step 1 (impregnation) can be skipped and you can apply LAB Bathroom Coating Primer directly. For gypsum-based stucco, plasterwork and Ytong blocks of aerated concrete, we recommend using Renovlies instead of LAB Bathroom Coating Impregnation. After applying Renovlies, you can get started with LAB Bathroom Coating Primer.
Consumption: 5 to 8 m² per kilo. The yield depends on the substrate, pretreatment, method of application, applied layer thickness, processing material and conditions. Apply LAB Bathroom Coating Primer in 1 or 2 layers. Rough, absorbent substrates require 2 layers for good layer thickness and coverage. Bright and very light colours cover less well. Two layers are also advisable in this case.
LAB Bathroom Coating
LAB Bathroom Coating is a colourfast coating that does not yellow. The coating is impact and scratch resistant and easy to clean.
You apply LAB Bathroom Coating to surfaces that have been treated with LAB Bathroom Coating Impregnator (only necessary for absorbent surfaces) and/or LAB Bathroom Coating Primer.
Consumption: 7 to 10 m² per kilo. The yield depends on the substrate, pretreatment, method of application, applied layer thickness, processing material and conditions. Apply LAB Bathroom Coating in two layers. It is important that you have already obtained good coverage with LAB Bathroom Coating Primer in step 2, especially with bright and white colours. Otherwise, two layers of coating may not be sufficient for a covering end result.
We do not recommend using the entire LAB Bathroom Coating system on the floor in the wet room of the bathroom.
How do you calculate the required quantity?
Measure the length and width of the surface you are going to treat. Multiply this by each other and then divide this by the consumption per kilo. Now you know how many kilos you need for 1 layer. For example: for a surface of 5 mx 2 m (10 m² : 8 m² = 1.25 kilos) you need 1.25 kilos of LAB Bathroom Coating Impregnation for 1 layer (calculated with a consumption of 8 m² per kilo).
Order the complete and reduced price Bathroom coating processing package with these products. Then you know for sure that you have all the supplies for the job at home!
Rocky no. 169
Rocky no. 169 is a mid grey with which you will rock your interior. With this shade you go for a neutral base and you can still go in all directions. Combine Rocky no. 169 with other neutrals such as Pale Grey no. 93 and Loft no. 113 or seek excitement with Tout no. 530 and Terra Pink no. 102 .
LAB Bathroom Coating
LAB Bathroom Coating is an easy to use system specially developed for bathrooms and wet cells, such as the shower room (with the exception of the floor in the wet cell). Ideal if you do not want tiles. But can also be applied over tiles! The LAB Bathroom Coating system consists of three different products, namely: LAB Bathroom Coating Impregnator, LAB Bathroom Coating Primer and LAB Bathroom Coating.
It is important to read the product advice carefully before application!
LAB Bathroom Coating Impregnation
With LAB Bathroom Coating Impregnator you fix powdery surfaces and highly absorbent surfaces are quickly sealed. This makes the covering system of LAB Bathroom Coating easier and more even to apply and creates a good bond with the surface.
Is the surface not absorbent? Then this step is not necessary.
Consumption: 6 to 10 m² per kilo. The yield depends on the substrate, pretreatment, method of application, applied layer thickness, processing material and conditions. Apply LAB Bathroom Coating Impregnator in 1 layer.
LAB Bathroom Coating Primer
LAB Bathroom Coating Primer provides excellent adhesion and colour coverage. For absorbent surfaces, first treat the bathroom with LAB Bathroom Coating Impregnation. If the surface is not absorbent (such as tiles and bathrooms that have already been painted or coated), step 1 (impregnation) can be skipped and you can apply LAB Bathroom Coating Primer directly. For gypsum-based stucco, plasterwork and Ytong blocks of aerated concrete, we recommend using Renovlies instead of LAB Bathroom Coating Impregnation. After applying Renovlies, you can get started with LAB Bathroom Coating Primer.
Consumption: 5 to 8 m² per kilo. The yield depends on the substrate, pretreatment, method of application, applied layer thickness, processing material and conditions. Apply LAB Bathroom Coating Primer in 1 or 2 layers. Rough, absorbent substrates require 2 layers for good layer thickness and coverage. Bright and very light colours cover less well. Two layers are also advisable in this case.
LAB Bathroom Coating
LAB Bathroom Coating is a colourfast coating that does not yellow. The coating is impact and scratch resistant and easy to clean.
You apply LAB Bathroom Coating to surfaces that have been treated with LAB Bathroom Coating Impregnator (only necessary for absorbent surfaces) and/or LAB Bathroom Coating Primer.
Consumption: 7 to 10 m² per kilo. The yield depends on the substrate, pretreatment, method of application, applied layer thickness, processing material and conditions. Apply LAB Bathroom Coating in two layers. It is important that you have already obtained good coverage with LAB Bathroom Coating Primer in step 2, especially with bright and white colours. Otherwise, two layers of coating may not be sufficient for a covering end result.
We do not recommend using the entire LAB Bathroom Coating system on the floor in the wet room of the bathroom.
How do you calculate the required quantity?
Measure the length and width of the surface you are going to treat. Multiply this by each other and then divide this by the consumption per kilo. Now you know how many kilos you need for 1 layer. For example: for a surface of 5 mx 2 m (10 m² : 8 m² = 1.25 kilos) you need 1.25 kilos of LAB Bathroom Coating Impregnation for 1 layer (calculated with a consumption of 8 m² per kilo).
Order the complete and reduced price Bathroom coating processing package with these products. Then you know for sure that you have all the supplies for the job at home!